Choosing underlayment

Underlay smooths small bumps, reduces noise and protects against moisture. The wrong one can ruin a click joint.

As an Amazon Associate I earn from qualifying purchases.

What underlay does

Types

TypeGood forNotes
PE or XPS foam, 2–3 mmLaminate on a budgetLight, cheap; limited sound reduction
Wood fibreboard, 5–7 mmLaminate on uneven timber floorsBridges small dips; not for underfloor heating
Rubber or mineral-filled, 1–2 mmVinyl, laminate, upstairs flatsDense, good impact sound, often heating-friendly
Cork, 2–4 mmWood and laminateNatural, warm, good sound

What goes under your floor

The right layers depend on two things: the floor you are laying and what it is going on. Find your combination below. Layers are listed from the subfloor up.

Laying it onLaminate or engineered woodClick vinyl (LVT, SPC)Solid hardwoodTile
Concrete or screedPE foil vapour barrier (6 mil / 0.15 mm or as specified), then 2–3 mm foam or cork. Or one foam underlay with the barrier built in.PE foil, then 1–1.5 mm dense vinyl underlay. Foil still goes down if the pad is attached, unless the box says it has a barrier.No nailing: glue down over a moisture-barrier primer, or fit 18 mm plywood first.No underlay. Primer, then tile adhesive. Add an uncoupling membrane over underfloor heating.
Wooden floorboardsLaminate: wood fibreboard 5–7 mm, laid across the boards. Engineered: an approved underlay, with a Class II retarder under it over an unheated space. No plastic foil.1–1.5 mm dense vinyl underlay. No plastic foil. Boards must be flat.Over an unheated space, a Class II retarder such as #15 felt; over a heated room, none needed. Diagonal to old boards that run square to the joists, or overlay with 15 mm (19/32") plywood.Never directly, and not backer board alone. Plywood overlay first, then an uncoupling membrane or backer board.
Plywood, chipboard or OSB2–3 mm foam or cork. No plastic foil.1–1.5 mm dense vinyl underlay.As for floorboards. At least 15 mm (19/32") plywood or 18 mm (23/32") OSB on 40 cm (16") joists; chipboard cannot be nailed into. Run perpendicular to the joists.Primer for wood, then an uncoupling membrane.
Old tilesPE foil if the tiles are on concrete, then foam or cork.Fill the grout lines, then dense vinyl underlay (foil if on concrete).No nailing. Glue down with an approved adhesive after filling wide grout joints, or remove the tiles.Bonding primer on clean, firmly stuck tiles.
Old vinyl or linoFoam or cork, if the old floor is stuck down flat. It already blocks moisture.Dense vinyl underlay, if the old floor is flat and stuck down.Nail through if well stuck down (max 2 layers, 5 mm), with nails reaching 16 mm into the wood below. Never sand it: old vinyl may contain asbestos.Remove it first. Adhesive does not bond to vinyl.

Underfloor heating or a flat with neighbours below changes the underlay: pick a thin heating-rated type, or a dense acoustic type. The planner works this out for your room and adds it to your shopping list.

Why no foil on wood

Plastic foil stops moisture rising from concrete, which is what you want. On a wooden subfloor it does the opposite job: it traps the moisture the wood gives off, and the boards underneath can go mouldy or rot. Use a breathable underlay such as fibreboard or cork there instead.

Vapour retarders under wood on a wooden subfloor

For solid or engineered wood over a wooden subfloor, the 2025 NWFA guidelines make it depend on what is below. Over a heated room kept at the same conditions as the living space, no vapour retarder is needed unless the flooring maker asks for one. Over an unheated space such as a crawlspace or garage, a Class II retarder may be used to slow moisture coming up: #15 asphalt-saturated felt is the common choice, or a sheet or liquid product the maker approves. Plain rosin paper is not a vapour retarder.

A retarder is never a fix for a known moisture problem. Find and fix the source before laying any wood floor.

Rules of thumb

Browse flooring underlayment on Amazon

Wood flooring guidance on this page follows the NWFA Wood Flooring Installation Guidelines (2025 edition) from the US National Wood Flooring Association, written for North America. In Europe, national codes apply instead, such as BS 8201 in the UK and DIN 18356 in Germany, and climate ranges often differ. Your flooring maker's instructions come first: if they say something different, follow them.